CHAPTER 3 SPECIFICATIONS
3
3.1 Gener
al Specifications
CHAPTER 3
SPECIFICATIONS
This chapter describes the specifications of the Ethernet adapter module.
3.1
General Specifications
*1
Do not use or store the Ethernet adapter module under pressure equivalent to the atmospheric pressure of an elevation
of 0m or higher. Doing so may cause malfunction. When applying pressure to the module, please consult your local
Mitsubishi representative.
of 0m or higher. Doing so may cause malfunction. When applying pressure to the module, please consult your local
Mitsubishi representative.
*2
This indicates the section of the power supply to which the equipment is assumed to be connected between the public
power distribution network and the machinery within premises.
Category II applies to equipment for which electric power is supplied from fixed facilities. The surge voltage withstand
level for up to the rated voltage of 300V is 2500V.
power distribution network and the machinery within premises.
Category II applies to equipment for which electric power is supplied from fixed facilities. The surge voltage withstand
level for up to the rated voltage of 300V is 2500V.
*3
This index indicates the degree to which conductive material is generated in terms of the environment in which the
equipment is used.
At pollution level 2, only non-conductive pollution occurs. A temporary conductivity caused by condensing must be
expected occasionally.
equipment is used.
At pollution level 2, only non-conductive pollution occurs. A temporary conductivity caused by condensing must be
expected occasionally.
For compliance with the EMC directive, refer to "EMC and Low Voltage Directives" in this manual.
(
(
Item
Specification
Operating ambient
temperature
temperature
0 to 55°C
Storage ambient
temperature
temperature
-25 to 75°C
Operating ambient
humidity
humidity
5 to 95%RH, non-condensing
Storage ambient
humidity
humidity
Vibration resistance
Compliant with
JIS B 3502 and
IEC 61131-2
Frequency
Constant
acceleration
Half amplitude
Sweep count
Under
intermittent
vibration
5 to 8.4Hz
3.5mm
10 times each in
X, Y, and Z
directions
8.4 to 150Hz
9.8m/s
2
Under
continuous
vibration
5 to 8.4Hz
1.75mm
8.4 to 150Hz
4.9m/s
2
Shock resistance
Compliant with JIS B 3502 and IEC 61131-2 (147m/s
2
, 3 times each in X, Y, and Z directions)
Operating atmosphere
No corrosive gases
Operating altitude
*1
0 to 2000m
Installation location
Inside a control panel
Overvoltage category
*2
II or lower
Pollution degree
*3
2 or lower
Equipment class
Class I