Diagnostics
59
Running Diagnostics from the Terminal Port
1.  To run the internal diagnostic programs from the terminal port, turn off the T1 Modem Bank and connect a
terminal to the terminal port. Some terminals will not transmit data if their CTS (Clear To Send) line is LOW.
These terminals must have their CTS line HIGH or floating to ensure that they will have no problems
communicating with the T1 Modem Bank. Appendix C on page 91 shows a cable that can be used for these
terminals.
2.  Power up the terminal and set its communications parameters to 9600 baud, 8 data bits, no parity and 1 stop bit.
3.  Turn the T1 Modem Bank back on and wait for the POST to complete. While 
P1
 is displayed on the front panel,
press the letter 
V
 (either upper or lower case) on your terminal.
You will see the following screen:
Digi International T1 Modem Bank
  ROM revision: 0x1400 Rev X [C] Digi International, 1996. All rights reserved
  ROM startup (cold boot)
Instruction cache size: 0x00001000
       Data cache size: 0x00000800
              RAM size: 0x00400000
CPU test............passed
Watchdog test.......passed
ROM checksum test...passed
Simple
RAM test............0xA0001000-0xA03F0010 passed
Complex
RAM test............0xA0001000-0xA0002000 passed
Timer test..........passed
Sync test...........passed
Line Card test…………….passed
Modem test……………………..passed
T1 line=AMI/D4 Signaling=AT&T Long Haul Jitter=IN EGL=26 LBO=-22.5
D&I Line=AMI/D4 Signaling=AT&T EQ=0.6
Node number.........1
Press '?' for diagnostics menu
or carriage return to download