Справочник Пользователя для Sun Microsystems T3

Скачать
Страница из 88
42
Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001
Dual Hosts With Two Hubs and Four Controller
Units Configured as Two Partner Groups
shows two application hosts connected through FC-AL cables to two hubs
and four Sun StorEdge T3+ arrays forming two partner groups. This multi-initiator
configuration 
can be used for footprint and I/O throughput.
Note –
This configuration is a recommended enterprise configuration for RAS
functionality because the controller is not a single point of failure.
Note –
There are no hub port position dependencies when connecting arrays to a
hub. An array can be connected to any available port on the hub.
Each array needs to be assigned a unique target address using the port set
command. These target addresses can be any number between 1 and 125. At the
factory, the array target addresses are set starting with target address 1 for the
bottom array and continuing to the top array. Use the port list command to
verify that all arrays have a unique target address. Refer to Appendix A of the Sun
StorEdge T3 and T3+ Array Administrator’s Guide 
for further details.
The following three parameters must be set on the master controller unit, as follows:
mp_support = rw
or mpxio
cache mode = auto
cache mirroring = auto
Note –
For information on setting these parameters, refer to the Sun StorEdge T3 and
T3+ Array Administrator’s Guide
Host-based multipathing software is required for this configuration.