Features
Matrix X16-C Chassis Installation Guide 1-7
7.
Again, you can enter the show system high‐availability command to verify synchronization 
is complete and the standby CM is up. Note in the output that the Standby Module status has 
changed from Synchronizing to In‐Service.
SYSTEM HIGH-AVAILABILITY INFORMATION
------------------------------------
System Coldstart: 
Wed Mar  9 12:28:24 2005
Current Time: 
Wed Mar  9 18:36:06 2005
Total System Uptime: 
0d06h07m42s
HA-Channel: 
Primary - Online
Configuration: 
Warm-Redundant (Failover = Coldstart)
Total Failovers Since Coldstart:
0
Early Repetitive Failure Protection: 10m00s, Expired
CONTROL MODULE INFORMATION
--------------------------------
CM1
In-Service
Active
Uptime:0d00h54m08s
1.3.2.N
CM2
In-Service
Standby
Uptime:0d00h05m36s
1.3.2.N
MONITOR VALUES
--------------------------------
Scan Interval:
 60s
(default)
In-use memory threshold:
 85%
(default)
Memory change delta:
 10240KB
(default)
Cpu Usage threshold:
80.0% (default)
Be aware that if the active CM resets during the synchronization (for example, due to a software 
fault, operator command, power‐loss, or other system problem), you do not need to take action. 
The system will fully recover on its own during the next system restart, assuming that both CMs 
are left installed in the chassis. However, physically removing the active CM during the process 
may cause configuration data loss.
Proper CM Recovery
If you want to ensure that a certain configuration wins arbitration over another after a “physical 
loss,” the solution is to allow the CM it is stored on to become active first. This can be 
accomplished in one of two ways:
1.
Install only one CM in the chassis.
2.
Do not allow the other CM to boot until after the good CM has declared itself active.
For example, say the mistake you made was to reinsert an installed CM (CMa in an originally 
single CM chassis) back into the running system knowing that there was already an active CM 
(CMb) running. One solution would be to physically remove CMb, insert CMa, allow it to become 
active, then insert CMb. The configuration contained on CMa will then be restored.
X16-C Fabric Module
The Matrix X16‐C provides a Fabric Module (FM) which connects multiple IOMs to form an 
integrated system. Current IOMs require dual FMs to support line rate traffic. Both are in Active 
mode.