Section: 3.10 Error and warning messages
Scali MPI Connect Release 4.4 Users Guide 
33
3.9.5 Unsafe MPI programs
Because of different buffering behavior, some programs may run with MPICH, but not with 
SMC. Unsafe MPI programs may require resources that are not always guaranteed by SMC, and 
deadlock might occur (since SMC uses spin locks, these may appear to be live locks). If you 
want to know more about how to write portable MPI programs, see for example MPI: The 
complete reference: vol. 1, the MPI core
 [2].
A typical example that will not work with SMC (for long messages):
while (...) {
MPI_Send(buf, cnt, dtype, partner, tag, comm);
MPI_Recv(buf, cnt, dtype, MPI_ANY_SOURCE, MPI_ANY_TAG, comm, sts);
doStuff();
}
Thsi code tries to se the same buffer for both sending and receiving. Such logic can be found, 
e.g., where processes from a ring where they communicate with their neigbours. Unfortunately 
writing the code this way leads to deadlock, and to make it work the MPI_Send() must be 
replaced with MPI_Isend() and MPI_Wait(), or the whole construction should be replaced with 
MPI_Sendrecv() or MPI_Sendrecv_replace().
3.9.6 Name space pollution
The SMC library is written in C and all of its C names are prefixed with scampi_. Depending 
on the compiler used, the user may run into problems if he/she has C code using the same 
scampi_ prefix. In addition, there are a few global variables that may cause problems. All of 
these functions and variables are listed in the include files mpi.h and mpif.h. Normally, these 
files are installed in /opt/scali/include.
Given that SMC has not fixed its OS routines to specific libraries, it is good programming 
practice to avoid using OS functions or standard C-lib functions as application function names. 
Naming routines or global variables as sendrecvopencloseyieldinternal_error
failureservice or other OS reserved names may result in an unpredictable and undesirable 
behavior.
3.10 Error and warning messages
3.10.1 User interface errors and warnings
User interface errors usually result from problems where the setup of the environment causes 
difficulties for mpimon when starting an MPI program. mpimon will not start before the 
environment is properly defined. These problems are usually easy to fix, by giving mpimon 
the correct location of the necessary executable. The error message provides a straight forward 
indication of what to do. Thus, only particularly troublesome user interface errors will be listed 
here.
Using the -verbose option enables mpimon to print more detailed warnings. 
3.10.2 Fatal errors
When a fatal error occurs, SMC prints an error message before calling MPI_Abort() to shut 
down all MPI-processes.