Chapter 6  Troubleshooting and Diagnostics 
Installation and Operation Manual 
6-8 Handling 
Alarms
 
ASMi-52 Ver. 2.5 
Clearing the E1/T1 Statistics 
 
To clear E1/T1 statistics: 
•  From the E1 Port Performances menu (see 
Figure 6-2
), select E1/T1 Clear 
Local Performances 
or E1/T1 Clear Remote Performances (Main menu > 
Monitoring > Physical Port Statistics > E1 Port Performances > E1/T1 Clear 
Local/Remote Performances), (see 
Figure 6-7
). 
All E1 statistics data are cleared. 
6.2 Detecting Errors 
Power-Up Self-Test 
ASMi-52 performs a hardware self-test upon power-up. The self-test sequence 
checks the critical circuit functions of the modem. 
The results of the hardware self-test for the local or remote ASMi-52 are displayed 
in the System Status and Physical Status Port screens (see 
Chapter 4
). 
Front Panel LEDs 
The status of ASMi-52 is indicated by the ALM, TST and SYNC LED indicators 
located on the front panel. For the description of LEDs and their functions, refer to 
Chapter 3
6.3 Handling Alarms 
ASMi-52 detects fault conditions and initiates alarms to alert the user. ASMi-52 
supports the following alarm types: 
•  System alarms, relating to the ASMi-52 chassis 
•  Port alarms, relating to a specific interface (SHDSL or DTE) 
•  Information messages (warnings) 
•  Events that trigger alarm activation. 
ASMi-52 maintains two separate displays for the system and port alarms. In 
addition, the modem supports a local log file, holding up to 100 alarms.  
An alarm or warning simultaneously activates the alarms display and generates a 
log file, and the ALM LED turns on to indicate the condition. When the fault 
condition that caused the alarm is cleared, the alarm is removed from the alarm 
screen, but remains in the log file, enabling you to view the alarm history. Events 
are generated into the log file.