11 ATTO Technology BridgeTools Installation and Operation Manual
4.2 General panel
The general panel provides some basic information about the FibreBridge. A message box at the bottom 
of the panel displays useful hints and suggestions. Clicking on the help icon will give a detailed 
explanation of each parameter, the possible values to enter and how the FibreBridge will respond to each 
selection. Some parameters will be “grayed out” if they do not apply to your model of the FibreBridge 
or if they have no effect based upon the selected value of a related parameter. 
Blink Ready LED (default = disabled)
Enabling this option causes the Ready LED on the front 
panel of the FibreBridge to blink until you disable the 
parameter. Helps to identify the particular FibreBridge you 
are connected to in the SAN.
FibreBridge Name
An eight-character name assigned by the user to identify 
each FibreBridge on the network to help identify and select 
a specific FibreBridge.
FibreBridge Type
Read only: reports the type of FibreBridge in use.
Minimum Alarm Temperature
Sets and displays the enclosure temperature minimum 
threshold value. An alarm will trigger if the enclosure 
temperature drops below this value. Valid entries are 
between 5 and 40 degrees C and must be below the 
Maximum Alarm Temperature value.
Maximum Alarm Temperature
Sets and displays the enclosure temperature maximum 
threshold value. An alarm will trigger if the enclosure 
temperature goes above this value. Valid entries are between 
5 and 40 degrees C and must be above the Minimum Alarm 
Temperature value.
NVRAM Version
Read only: reports the revision level of the NVRAM within 
the FibreBridge. 
Power Status A 
Read only: allows remote monitoring of Power Supply A 
status. BridgeTools will report it as either OK or 
Unavailable.
Power Status B
Read only: allows remote monitoring of Power Supply B 
status. BridgeTools will report it as either OK or 
Unavailable.
Serial Number
Read only: serial number of FibreBridge currently 
connected to BridgeTools.
Temperature
Read only: allows remote monitoring of the FibreBridge 
internal temperature.
World Wide Name (WWN)
Read only: provides a guaranteed unique identifier for each 
Fibre Channel port on the network. This information can be 
used to persistently bind the port to a host target ID. 
Some options will be “grayed out” on the panel: they are not available because of the type of access mode or FibreBridge model or they have no effect based on other 
selections. The chart below shows options available based on model and access method.
Model/Access method
Options
2200/3200 
in-band
2200/3200 
Ethernet
2200/3200 
serial port
4500 
in-band
4500 
Ethernet
4500 
serial port
Blink Ready LED
FibreBridge name
FibreBridge type
Maximum Temperature
Minimum Temperature
NVRAM version
Power Status A
Power Status B
Serial number
Temperature
World Wide Name