21 ATTO Technology BridgeTools Installation and Operation Manual
4.9 Events panel
Event logs help to troubleshoot hardware failures. This panel configures the event logging features of 
the FibreBridge. Some parameters will be “grayed out” if they do not apply to your model of the 
FibreBridge or if they have no effect based upon the selected value of a related parameter. 
If the SAN is unable to detect or communicate with SCSI 
devices connected to the FibreBridge, you can examine the 
Event Log to determine if there is a hardware issue with the 
FibreBridge or if the problem is due to a configuration error.
If the FibreBridge is configured to log all events, the log can 
be lengthy and difficult to interpret. Log events as efficiently 
as possible by enabling logging for that section of the 
FibreBridge. 
Use BridgeTools to configure the type of event logging 
desired. To view the actual events, use either Serial or 
Ethernet communications tools such as FTP or Hyper 
Terminal. Refer to the FibreBridge manual for further 
details.
Clear all Events 
Erases all previously recorded event log entries.
Event Level (default = all active)
Selects the level of monitoring and logging. 
Event Logging (default = active)
Disables Event logging.
Event Subsystem (default = all active)
Selects which hardware subsystems are to be monitored. 
Select as many of the hardware systems as needed: 
➔ Fibre Channel
➔ SCSI, Ethernet
➔ GBIC
➔ NVRAM hardware systems
Some options will be “grayed out” on the panel: they are not available because of the type of access mode or FibreBridge model or they have no effect based on other 
selections. The chart below shows options available based on model and access method.
Access method
Options
2200/3200 
in-band
2200/3200 
Ethernet
2200/3200 
serial port
4500 
in-band
4500 
Ethernet
4500 
serial port
Clear All Events
Event Level
Event Logging
Event Subsystem