3.2.31  SafeCom (Message Type p) 
SIA Mode Description 
SafeCom 
Example 
<LF><CRC><p><sequence#><receiver#><line#>[#aaaa|EEEEdata]<CR> 
 
Table 87: 
SafeCom (Message Type p) Byte Description 
 
Title Description 
LF 
Standard line feed character.  
CRC 
Cyclical redundancy check number.  
Message 
sequence# 
The message sequence number. The valid sequence number range is 0001 to 9999. 
receiver# 
The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600.  
line# 
The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 
99. The receiver uses Line 0 (zero) for internal messages. 
account # 
The communicator's account number has four digits. 
EEEE 
Event code, four digits. 
data 
Event code parameter data.