Справочник Пользователя для Barco 8x8

Скачать
Страница из 90
22
MatrixPRO  •  16x16 and 8x8 HD/SD-SDI Router  •  User’s Guide
3.  Operation
Menu Structure
Please note:
When selecting the baud rate for either RS-232 or RS-485, the user has these 
choices:  1200, 2400, 9600, 38400, 57600.  
When selecting the byte format, the user has these choices:  
~
N81, (one start bit, eight data bits, one stop bit and no parity bit) 
~
E71, (one start bit, seven data bits, one stop bit, even parity) 
~
O71, (one start bit, seven data bits, one stop bit, odd parity.)  
Hardware handshaking can be set to ON or OFF.  
opJQUR=pÉííáåÖë=jÉåì
From the System Menu, select 
RS-485 Settings
 to display the RS-485 Settings Menu.
Figure 3-9.  MatrixPRO RS-485 Settings Menu
This menu allows the adjustment of the node number in the conventional manner.  The 
node number can range from 1 to 32.  After a factory reset or an RS-232 menu reset, the 
default node number is set to 17.
fm=^ÇÇêÉëë
From the System Menu, select 
IP Address
 to display the IP Address Menu.
Figure 3-10.  MatrixPRO IP Address Menu
When this menu item is selected, the cursor (
^
) will be positioned under the right-most digit 
in the address.  Note that the default IP address is 192.168.000.242.
„
To adjust the IP address:
1.  The value of the number can be modified upward by rotating the selector knob 
clockwise (CW).
2.  Press SEL to update the number and advance the cursor one place to the left.
3.  Repeated presses of the SEL key will advance the cursor through the numeric 
fields, skipping the decimal-point field delimiter.  
RS-485 Settings
> Baud Rate
[57600]
Handshaking
[OFF]
Node Number
17
IP Address
192.168.000.242
^