Справочник Пользователя для GE GFK-1004B

Скачать
Страница из 268
4
4-32
TCP/IP Ethernet Communications  User’s Manual – January 1996
GFK-1004B
Table 4-5.  Minor Error Codes for Major Error Codes 5H and 85H (Continued)
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
Error Status
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Service Request Error Description
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
(Hexadecimal)
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
f705H/f785H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Required to log in to a task for service.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
f805H/f885H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Invalid task name referenced.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
f905H/f985H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Task address out of range.
ÁÁÁÁÁÁ
fc05H/fc85H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
I/O configuration is invalid.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
fe05H/fe85H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
No privilege for attempted operation.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
ff05H/ff85H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Service request has been aborted.
Table 4-6.  Minor Error Codes for Major Error Code 11H (at Remote  Server PLC)
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
Error Status
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SRTP Error Description
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
(hexadecimal)
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
0111H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Generic SRTP error.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
0211H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
The PLC is inaccessible.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
0311H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Reserved.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
0411H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Unexpected SRTP version encountered in received message.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
0511H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Unrecognized SRTP message received.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
0611H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Data present in SRTP message which should not contain data.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
0711H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Generic resource problem detected.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
0811H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SRTP message encountered in inappropriate connection state.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
0911H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Generic refusal by backplane driver to handle request.
ÁÁÁÁÁÁ
0a11H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Recognized but unsupported SRTP message received.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
0b11H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Lost transaction in server.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
1411H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Request failed due to an error in the remote device.  The Remote
device log will have more information.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
2711H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Backplane driver not initialized.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
2a11H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
The backplane driver could not access the PLC.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
2b11H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Invalid binding on the message sent to the backplane driver.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
2c11H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
The message could not be sent to its destination because the mailbox was
not open.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
2d11H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
The maximum number of transfers to the destination is already
taking place.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
2e11H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
The maximum number of transfers of this transfer type is 
already taking place.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
2f11H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Cannot obtain a backplane transfer buffer.
ÁÁÁÁÁÁ
3011H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Cannot obtain resources other than backplane transfer buffers.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
3111H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Connection ID or block transfer ID is not valid.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
3211H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Timed out waiting for PLC CPU response.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
3311H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
The PLC CPU aborted the request.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
3411H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
An invalid message type was specified.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
3511H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
The specified task is not registered.
ÁÁÁÁÁÁ
3611H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
The mailbox offset specified is invalid.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
3a11H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
More than the allowable byte length in a single transfer.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
3b11H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Bad sequence number in the request.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
3c11H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Invalid command in request.
ÁÁÁÁÁÁ
ÁÁÁÁÁÁ
3f11H
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Request failed due to error on remote device, most likely running out of Dual-
Port RAM text buffers.