Commissioning (software)
4.6 Using drive-related I/Os by SIMOTION
D410
Commissioning Manual, 08/2008 Edition
Commissioning Manual, 08/2008 Edition
105
Table 4-10 Global measuring inputs, configuration of the Measuring Input TO
Axis measuring system no. Under axis measuring system number, enter the number of the used
encoder system (namely, encoder 1, 2 or 3). Encoder system 1 is the
default setting.
Global measuring
Activate the checkbox when a global measuring input is used.
Enter here the logical HW address and the bit number of the used
Enter here the logical HW address and the bit number of the used
input.
Start address message frame 39x + 3, bit 1 for input DI/DO 9
Start address message frame 39x + 3, bit 2 for input DI/DO 10
Start address message frame 39x + 3, bit 1 for input DI/DO 9
Start address message frame 39x + 3, bit 2 for input DI/DO 10
Logical hardware address
and bit number:
Start address message frame 39x + 3, bit 3 for input DI/DO 11
Detailed information is contained in the
SIMOTION Motion Control Output Cams and
Measuring Outputs
Function Manual.
4.6.8
Outputs of cam outputs and probe inputs on TM15/TM17 High Feature
Quantity framework for TM15/TM17 High Feature
The TM15/TM17 High Feature Terminal Modules can be used to extend the number of
outputs for cam outputs and probe inputs that can be installed.
● TM15, maximum 24 outputs for cam outputs / probe inputs
● TM17 High Feature, maximum 16 outputs for cam outputs / probe inputs
● TM15, maximum 24 outputs for cam outputs / probe inputs
● TM17 High Feature, maximum 16 outputs for cam outputs / probe inputs
Additional references
Detailed information for the configuration is contained in the following documents
● SIMOTION Output Cams and Measuring Inputs Function Manual
● TM15/TM17 High Feature Terminal Modules Commissioning Manual
● SIMOTION Output Cams and Measuring Inputs Function Manual
● TM15/TM17 High Feature Terminal Modules Commissioning Manual