Справочник Пользователя для Philips SPX 15-35

Скачать
Страница из 14
SPX Operation Manual 
 
 
 
 
 
 
Version 1.1: 2010         © 2010 Philips Selecon All Rights Reserved
 
 
Operating your Luminaire 
Please  note  that  as  the  handles  and  knobs  on  the  SPX  range  can  reach  high  temperatures 
depending  on  the  position  or  orientation  of  the  luminaire,  gloves  should  always  be  worn  when 
focusing these luminaires. 
Pan and Tilt Adjustment   
To  pan  the  luminaire,  loosen  the  nut  at  the  top  of  the  yoke  and  adjust,  then  retighten.    To  tilt,  loosen  the 
locking clamp handle on the side of the luminaire, tilt and retighten finger tight.  
 
An additional tilt locking clamp can be added to the other side of the 
yoke if required ( code: SPXTLOKIT). To fit, remove the yoke bolt 
cover with a flat blade screwdriver, and undo the M8 yoke bolt with a 
13mm / ½” socket wrench. Gently lever open the yoke slightly and 
insert the cup head bolt in the yoke lock off hole. Add the spring and 
washer from the kit and then the locking clamp. Retighten the M8 yoke 
bolt, taking care to avoid over tightening, and replace the yoke bolt 
cover.  
 
The tilt scale is displayed in real degrees and allows for accurate 
presetting of your luminaire and matching other luminaires in your rig.  
 
Focusing SPX Zoomspot Models  
The beam of the SPX can be adjusted to a well controlled soft-edged focus useful when merging one beam to 
the  next,  or  to  a  hard-edged  focus  useful  for  projections,  specials,  etc.  The  variable  beam  of  your  SPX 
luminaire is altered by adjusting the front or rear lens in relation to 
each other.  The front lens defines the beam spread; the rear, the 
focus  degree  of  "softness"  or  "sharpness"  of  the  beam  edge  or 
shutters.   
To focus your zoomspot, first define the beam size required using 
the  front  lens.  Then  set  the  hardness/  softness  of  the  beam  with 
the focus lens. A reference scale is on the bottom of the lens tube. 
The  reference  scale  allows  you  to  record  your  preferred  beam 
settings. 
Finger tight pressure only is necessary to lock the lens off in their 
chosen positions. 
Focusing SPX Fixed Beam Profiles  
The lens can be moved to adjust the beam to in focus (sharp), or out of focus (soft). A 
focus direction label is on the bottom of the lens tube.  
To set a soft 
focus, move the lens forward of the 
hard focus 
position.  
 
 
NB: If you move it too far, the beam will become unusable and may cause the colour filter to fail prematurely.  
Shutter System 
The shutters are used to mask a portion of the beam, shaping it, masking light off scenery, curtains, etc.  Note 
that on the SPX range of luminaires, individual shutters are not removable. 
 
 
 
NOTE: Do not run the luminaire with the shutters fully closed, as this may cause the luminaire to 
over-heat