By connecting a computer to the projector with a RS-232C cross cable (D-sub 9 pins), you can control the projector with 
the computer. The commands to control the projector and the response data format against the received commands are 
explained here.
For details, please consult the authorized dealer where you purchased your projector.
1. Communication Specifications
The communication specifications are as follows.
Baud Rate
9600 bps / 19200 bps
Data Length
8 bits
Parity
None
Stop Bit
1 bit
Flow Control
None
2. Command Format
 
2-1 Command Data Format
 
 
When sending a control command to the projector, use the following data format.
 
 
Header      ID      SP      Command   [  SP     Parameter  ]    CR
 
 
Header  
 
: Designates the head of data and the data type.   
 
 
 
 
 
 
 
 
: ! (21h): Assigns command to the projector. 
 
 
 
 
 
 
 
 
 
: ? (3Fh): Query to the projector. (Asking command) 
 
 
 
 
 
ID  
 
 
: 1: The identification number of the projector. (Manufacturer set value 1) 
 
 
SP  
 
 
: Designates the delimiter for ID, Command, and Parameter. (20h) 
 
 
 
CR  
 
 
: Designates the terminal of the data. (0Dh) 
 
 
 
 
 
 
* [   ] is not necessary for Asking command.
 
2-2 Response Data Format
 
 
When sending a control command to the projector, use the following data format.
 
 
Header      ID      SP      Normal Termination Status    [  SP     Parameter  ]    CR
 
 
Header  
 
: Designates the head of data.   
 
 
 
 
 
 
 
 
 
 
: @ (40h): Fetches data from the projector. 
 
 
 
 
 
 
ID  
 
 
: 1: The identification number of the projector. (Manufacturer set value 1) 
 
 
SP  
 
 
: Designates the delimiter for ID, Command, and Parameter. (20h) 
 
 
 
Normal Termination Status : 0 (30h) 
 
 
 
 
 
 
 
 
 
 
CR  
 
 
: Designates the terminal of the data. (0Dh) 
 
 
 
 
 
2-3 Parameters Used For The Data Format
 
 
The following three kinds of parameters are used for control commands and response data.
 
 
1) Numeric value
 
 
2) ON/OFF
 
 
3) Special parameters
 
 
Each parameter is as follows:
 
 
1) Numeric value
 
 
    A 2-byte hexadecimal value (sign included) is represented by a set of 4 digit (4 bytes) characters.
 
 
    Designated range: 8000 to 7FFF.
 
 
2) ON/OFF
 
 
    Shows the status (ON/OFF) of the projector, such as POWER and MUTE.
RS-232 EXTERNAL CONTROL
42
Character
Hex.
Meaning
0
30
OFF
1
31
ON