DLP Projector—User’s Manual 
— 58 — 
A
PPENDIX 
RS-232C Protocol 
RS232 Setting
 
Baud rate: 
115200 
Parity check: 
None 
Data bit: 
Stop bit: 
Flow Control 
None 
RS-232 Setup for D5180 / D5185 
In the main HyperTerminal window, 
1.  Select “Property” from the “File” Menu  
2.  Select “Setting” Tab 
3.  Select “VT100” under Emulation 
   
 
4.  Click on “ASCII Setup” 
5.  Tick the options as below 
6.  Click OK while done 
   
 
Control Command Structure 
       
 
 
Header code 
Command code 
Data code 
End code 
HEX 
 
 Command Data 0Dh 
ASCII ‘V’  Command  Data  CR