3.6 Command Control via the Network (continued)
Command Format
Command formats differ among the different communication ports.
●  TCP #23 
You can use the RS-232C commands without any changes. The reply data 
format is the same as the RS-232C commands. However, the following reply 
will be sent back in the event of authentication failure when authentication is 
enabled.
Header
Data length
RS-232C command
Check sum Connection 
ID
0x02
0x0D
3 bytes
 byte
 byte
Reply
Error code
0x1F
0x04
0x00
<Reply in the event of an authentication error>
Header 
→  0x02, Fixed
Data length 
→  RS-232C commands byte length (0x0D, Fixed)
RS-232C commands  →   RS-232C commands that start with 0xBE 0xEF  
(13 bytes)
Check Sum 
→   This is the value to make zero on the addition of the 
lower 8 bits from the header to the checksum.
Connection ID 
→   Random value from 0 to 255 (This value is attached 
to the reply data)