50
Error Condition
0: No error
1: Lamp not lit after 5 
attempts
3: Lamp went out 
unexpectedly
4: Fan failure
5: Overtemperature
6: Low voltage
?: Query
ERR
R
0
6
0
1
Factory Reset
1: Reset
RST
W
1
Fan Position
0: Normal
1: Vertical
2: Down
FNP
RW
0
2
0
1
Firmware Version
FWV
R
string
Focus Far 
0: Fine Step
1: Large Step
MFF
W
0
1
1
1
Focus Near
0: Fine Step
1: Large Step
MFN
W
0
1
1
1
Gamma
0: Film
1: Graphics
2: Video
3: Linear
GTB
RW
0
3
Source 
Specific
1
Gateway Address
GT1: 1st Octet
GT2: 2nd Octet
GT3: 3rd Octet
GT4: 4th Octet
GTn
RW
0
255
0
1
Green Gain
GCG
RW
0
200
100
1
Green Offset
GCO
RW
0
200
100
1
High Altitude Mode
HAL
RW
0
1
0
1
Horz. Keystone
DHK
RW
-350
350
0
1
Horz. Refresh Rate
QHR
R
string
Horz. Total
HZT
RW
0
200
100
1
Horz. Position
HPS
RW
0
200
100
1
Horz. Phase
HPH
RW
0
200
100
1
Input Lock
0: Auto
1: 48Hz
2: 50Hz
3: 60Hz
ILC
RW
0
3
0
1
IP Address
IP1: 1st Octet
IP2: 2nd Octet
IP3: 3rd Octet
IP4: 4th Octet
IPn
RW
0
255
0
1
Lamp 1 Hours
?: Query
LMP
R
0
n/a
string
1
Lamp 1 Reset
1: Reset
LMR
W
1
Lamp 1 Status
0: Off
1: On
DLS
R
0
1
1
1
Lamp 2 Hours
?: Query
LDH
R
0
n/a
string
1
Lamp 2 Reset
1: Reset
LDR
W
1