Справочник Пользователя для Kramer Electronics VP-725XLA

Скачать
Страница из 67
Configuring and Controlling the VP-725XLA 
 
37 
37 
 
8.1.8.1  The Advanced Setup Screen 
 to 
, and 
 define the Advanced Setup 
screens. 
 
Figure 21: Advanced Setup Screen 
The Mode Set functions define the desired working resolution and refresh rate 
when the system cannot distinguish between similar resolutions and refresh 
rate values (see 
). 
Table 14: Mode Set Functions  
Setting 
Function 
Selection/Range 
Default 
Mode 1 
Set mode 1 
1400x1050x60Hz 
1680x1050x60Hz 
1400x1050x60Hz 
Mode 2 
Set mode 2 
1280x1024x75Hz 
1280x1024x76Hz 
1280x1024x75Hz 
Mode 3 
Set mode 3 
1280x768x60Hz 
1366x768x60Hz 
1280x768x60Hz 
Table 15: OSD Functions  
Setting 
Function 
Selection/Range 
Default 
Menu Position 
Set the location of the OSD 
menu 
Center, Top Left, Top Right 
Bottom Left, Bottom Right 
Top Right 
Time Out (sec) 
Set the OSD menu timeout  
5, 10, 20, 30, 60, 90 or Off  30 
 
Figure 22: Misc Setup Screen