Справочник Пользователя для Source Technologies ST9530

Скачать
Страница из 70
Secure MICR Printer User’s Guide 
 
 
© Source Technologies 
September 2005 
39
 
 
All Rights Reserved 
 
 
 
Audit Report Field Five 
&%SQ5d..d$
 
&%SQ5 
Lead in sequence 
d..d 
Data to be printed 
$ Command 
terminator 
 
This command identifies the data to be printed in the fifth column of the report.  This field is a 
maximum of eight characters.   
 
Audit Report Field Six 
&%SQ6d..d$
 
&%SQ6 
Lead in string 
d..d 
Data to be printed 
$ Command 
terminator 
 
This command identifies the data to be printed in the sixth column of the report.  This field is 
a maximum of 19 characters. 
 
Audit Report Field Seven 
&%SQ7d..d$
 
&SQ&7 
Lead in string 
d..d 
Data to be stored 
$ Command 
terminator 
 
This command identifies the data to be printed in the seventh column of the report.  This field 
is a maximum of 12 characters. The data in this field is recorded for the Audit Report only. 
 
Print and Purge Audit Report 
&%SPURGExx$
 
&%SPURGE 
Lead in string 
x option(s) 
$ Command 
terminator 
 
This command prints and purges the Audit Report. All recorded information is deleted.  The 
optional field can be any combination of the following letters: 
 
Total Field 4 
O Overlay 
Sort by MICR line 
 
Communicate - send report to host instead of printing  - see additional  
 
 
information below on SPRINT command