Справочник Пользователя для Star Micronics 150
Control Codes
PcOS Series 150
Programmer's Guide
EPOS Deviations
Page 72
Rev G
12/14/99
Function
Set print direction
ASCII
[ESC] T <n>
Description
The Series 150 Printer does not implement page mode. This command
uses the normal rotated print format procedures. See [ESC] r <n> in
normal mode.
uses the normal rotated print format procedures. See [ESC] r <n> in
normal mode.
Note: EPOS reverses Modes 1 and 3.
Function
Print graphics
ASCII
[ESC] * <m> <n>
1
<n>
2
Description
The Series 150 Printer defines the extended graphic modes. Mode 4 is
normally 80 dpi. The Series 150 Printer does not support 80 dpi. If
Mode 4 is selected, 72 dpi will be used.
normally 80 dpi. The Series 150 Printer does not support 80 dpi. If
Mode 4 is selected, 72 dpi will be used.
Print n1 + 256 * n2 bytes of graphics where m specifies the density.
Where m
0
Single-density graphics
60 dpi
1
Double-density graphics
120 dpi
2
Double-density half-speed graphics
120 dpi
3
High-density graphics
240 dpi
4, 5
CRT II screen
72 dpi
6
CRT I screen
90 dpi
7
Dual plotter
144 dpi
Function
Turn 90
°°
clockwise font ON/OFF
ASCII
[ESC] V <n>
Description
The Series 150 Printer uses the rotated 90
°
font to implement this
command. If one dot spacing is selected, ten cpi is used. If 1.5 dot
spacing is selected, eight cpi is used.
spacing is selected, eight cpi is used.
Function
Select print paper
ASCII
[ESC] c 0 <n>
Description
The Series 150 Printer uses this command to select a print station. The
Series 150 Printer does not keep track of different settings for each
mode. If a specific print mode is required, it must be respecified.
Series 150 Printer does not keep track of different settings for each
mode. If a specific print mode is required, it must be respecified.
Function
Select print paper for setting
ASCII
[ESC] c 1 <n>
Description
The Series 150 Printer does not keep track of different settings for
each mode. If a specific print mode is required, it must be respecified.
each mode. If a specific print mode is required, it must be respecified.
Function
Select detectors to stop printing
ASCII
[ESC] c 4 <n>
Description
The Series 150 Printer does not stop at the end of forms. The
application must keep track of the form length.
application must keep track of the form length.