Control Codes
PcOS Series 150
Programmer's Guide
EPOS Deviations
Page 72
Rev G
12/14/99
Function
Set print direction
ASCII
[ESC] T <n>
Description
The Series 150 Printer does not implement page mode. This command
uses the normal rotated print format procedures. See [ESC] r <n> in
normal mode.
Note: EPOS reverses Modes 1 and 3.
Function
Print graphics
ASCII
[ESC] * <m> <n>
1
 <n>
2
Description
The Series 150 Printer defines the extended graphic modes. Mode 4 is
normally 80 dpi. The Series 150 Printer does not support 80 dpi. If
Mode 4 is selected, 72 dpi will be used.
Print n1 + 256 * n2 bytes of graphics where m specifies the density.
Where m
0
Single-density graphics
60 dpi
1
Double-density graphics
120 dpi
2
Double-density half-speed graphics
120 dpi
3
High-density graphics
240 dpi
4, 5
CRT II screen
72 dpi
6
CRT I screen
90 dpi
7
Dual plotter
144 dpi
Function
Turn 90
°°
 clockwise font ON/OFF
ASCII
[ESC] V <n>
Description
The Series 150 Printer uses the rotated 90
°
 font to implement this
command. If one dot spacing is selected, ten cpi is used. If 1.5 dot
spacing is selected, eight cpi is used.
Function
Select print paper
ASCII
[ESC] c 0 <n>
Description
The Series 150 Printer uses this command to select a print station. The
Series 150 Printer does not keep track of different settings for each
mode. If a specific print mode is required, it must be respecified.
Function
Select print paper for setting
ASCII
[ESC] c 1 <n>
Description
The Series 150 Printer does not keep track of different settings for
each mode. If a specific print mode is required, it must be respecified.
Function
Select detectors to stop printing
ASCII
[ESC] c 4 <n>
Description
The Series 150 Printer does not stop at the end of forms. The
application must keep track of the form length.