C H A P T E R   1 :   G E T T I N G   S T A R T E D  
1 . 4 . 2   I n s t a l l i n g  
t h e  
H S 5 0 0 E  
1  Unpack and inspect the HS500E hardware and accessories. If an item 
appears to be damaged, notify your EMS distributor immediately. 
2  Securely mount the HS500E to your chosen location using four (4) #10 [M5] 
screws and matching locking washers and nuts. The HS500E may be 
mounted in any orientation, but should be aligned in such a manner that the 
four LED indicators can be seen during operation. 
3  Insert one end of a Category 5 Ethernet cable into the IP67 RJ45 connection 
housing. Install the RJ45 plug per the included instruction sheet. Attach the 
assembled mating connector to the HS500E and twist clock-wise one-half 
revolution. 
4  Connect the other end of the Ethernet cable to the Host or PLC network. A 
crossover cable (P/N: CBL-1479) may be required if connecting the HS500E 
directly to a computer (rather than to a switch, hub or router).  
5  Connect the female 4-pin M12 power supply cable to the male 4-pin M12 
connector on the HS500E.  
6  Turn the power supply ON. The Network and Error LEDs will flash 6 times (4 
slow, 2 fast), after which the antenna will be ready to receive commands. 
From the Host, connect to the HS500E and assign it a new IP address (see 
Chapter
 2 – IP Configuration). 
8  Note the new IP address on a sticker or label and attach it to the unit. 
9  Repeat these steps for each HS500E Antenna to be installed.  
 
Plan to perform a test phase and construct 
a small scale, independent network that 
includes only the essential devices 
required to test your RFID application. To 
avoid possible interference with other 
devices, do not, at first, connect the RFID 
testing environment to an existing office 
network. 