C H A P T E R   6 :   M O D B U S   T C P   P R O T O C O L  
CHAPTER 6:   
MODBUS
 
TCP
 
PROTOCOL 
 
One of the most popular and well-proven industrial automation protocols in use today 
is Modbus. Modbus TCP allows the Modbus protocol to be carried over standard 
Ethernet networks. 
6.1 
M
O D B U S  
T C P
 
O
V E RV I E W
 
Under the Modbus TCP protocol, the HS500E acts as a Modbus Server and the Host 
or PLC is the Modbus Client. By utilizing Produce and Consume registers for 
mapping commands and responses, data produced by the HS500E is consumed by 
the Modbus Client and data produced by the Modbus Client is consumed by the 
HS500E.  
NOTE
The Modbus Client (Host or PLC) must connect to the Modbus Server (HS500E) 
on port 502
Maximum number of words transferred to/from an RFID tag per read/write cycle: 
100 Words / 200 Bytes 
6 . 1 . 1  
M o d b u s   T C P   C o m m a n d   S t r u c t u r e  
M
A P P I N G  
N
O D E  
0 1
 
( C
O N S U M E  
R
E G I S T E R S
)
 
 
Consume Registers hold data destined for the HS500E. Modbus TCP commands 
must be placed in the holding registers of Device ID 1 (i.e. Node 01), starting at 
address 40001. Commands utilize at least six registers (double-byte values or words).   
Modbus 
Address 
(4xxxx / 
3xxxx) 
Read / Write 
Privilege 
Register Description 
(4000) 1  
R/W 
2-byte HS500E Consume Data Overall Length  
(> 0 indicates that data is available; HS500E clears to 
0 after data is processed) 
R/W 
MSB = Reader Type  
LSB = Command ID 
R/W 
MSB = 0x00 
LSB = Node ID (0x01) 
H S 5 0 0 E   –   O P E R A T O R ’ S   M A N U A L                                          
P / N :   1 7 - 1 3 0 5   R E V 0 2   ( 1 2 - 0 5 )  
P A G E   5 2   O F   8 2