Справочник Пользователя для Citizen Systems iDP-3551
ESC "c" "4" n
[Function]
Selecting the paper near end sensor valid for print stop
[Code]
<1B>H<63>H<34>H n
[Range]
0
≤
n
≤
255
[Outline]
This command selects the no-paper detector state in which printing should be stopped.
Value
Bit
Function
0
1
0
Paper near end
Disabled
Enabled
1
Undefined
−
−
2
Undefined
−
−
3
Undefined
−
−
4
Undefined
−
−
5
Undefined
−
−
6
Undefined
−
−
7
Undefined
−
−
[Default]
n = 0
ESC "c" "5" n
[Function]
Selecting the panel switch enable/disable
[Code]
<1B>H <63>H <35>H n
[Range]
0
≤
n
≤
255
[Outline]
This command enables/disables the panel switches. n is valid only for the least significant
bit.
bit.
Setting n = 1 disables the panel switches.
Setting n = 0 enables the panel switches.
Setting n = 0 enables the panel switches.
[Caution]
If the panel switches are disabled with this command, the LF switch will be disabled.
Therefore, the paper cannot be fed by the LF switch.
Therefore, the paper cannot be fed by the LF switch.
[Default]
n = 0
ESC "d" n
[Function]
Printing and n-line paper feed
[Code]
<1B>H <64>H n
[Range]
0
≤
n
≤
255
[Outline]
This command feeds the paper by n-lines after printing the one line worth of data saved in the
print buffer.
print buffer.