ESC "c" "4" n
[Function]
Selecting the paper near end sensor valid for print stop
[Code]
<1B>H<63>H<34>H n
[Range]
 n 
 255
[Outline]
This command selects the no-paper detector state in which printing should be stopped.
Value
Bit
Function
0
1
0
Paper near end
Disabled
Enabled
1
Undefined
2
Undefined
3
Undefined
4
Undefined
5
Undefined
6
Undefined
7
Undefined
[Default]
n = 0
ESC "c" "5" n
[Function]
Selecting the panel switch enable/disable
[Code]
<1B>H <63>H <35>H n
[Range]
 n 
 255
[Outline]
This command enables/disables the panel switches.  n is valid only for the least significant
bit.
Setting n = 1 disables the panel switches.
Setting n = 0 enables the panel switches.
[Caution]
If the panel switches are disabled with this command, the LF switch will be disabled.
Therefore, the paper cannot be fed by the LF switch.
[Default]
n = 0
ESC "d" n
[Function]
Printing and n-line paper feed
[Code]
<1B>H <64>H n
[Range]
 n 
 255
[Outline]
This command feeds the paper by n-lines after printing the one line worth of data saved in the
print buffer.