fn=4  Function 4 Sending the Set Memory Switch Value 
GS ( E pL pH fn a 
 
 
[Code] 
<
1D>H<28>H<45>H <pL><pH><fn><a> 
 
[Range] 
pL+pH×256)=2 
fn=4 
CT-S280
/
BD2-2220
 
a  = 1,2,3 
CT-S300
/
PMU2XXX
 
a  = 1,2,3,4 
CT-S2000
/
CT-S4000
/
CT-S310
 
a  = 1,2,3,4,5 
 
[Outline] 
[The specification which is common to the model]
 
• Sends the content of memory switch set in “a”.
 
 
 
Hex. 
No. of Data 
Header 37H 
ID 21H  1 
Data 30H 
or 
31H 
NULL 00H 
 
• Sends the set value of data in 8-byte data raw in order of bits 8, 7, 6, .... 
OFF: 30H (“0”) 
ON : 31H (“1”) 
 
[Caution] [The 
specification 
which depend on the model]
 
CT-S2000
/
CT-S4000
/
CT-S310
 
• MSW7 to MSW10 cannot be sent by this command. 
• Transmission is available by <Sending preset customize value>.