5.2 Bidirectional Parallel Interface 
 
Overview 
The interface of the printer is a Level-1 compatible device according to IEEE-P1284. It supports the communication 
modes described in 5.2.1 below. 
 
5.2.1 Parallel Interface Communication Mode 
The parallel interface of the printer provides three communication modes as outlined below. When the printer is 
turned on or reset, it defaults to Compatibility mode. 
 
• Compatibility Mode 
Data is transmitted from the host to the printer in units of one byte. Usually, this mode is used for data 
transmission. You may switch to the other modes from Compatibility mode. 
 
• Nibble Mode 
Data is transmitted from the printer to the host in units of four bits. The data transmission from the printer uses 
a status signal line. To send one byte of data in this mode, two sets of four-bit data are sent consecutively. 
 
• Byte Mode 
Data is transmitted from the printer to the host in units of one byte. Data transmission from the printer uses an 
8-bit data signal line. For Byte mode, the host must be capable of toggling the signal direction over the 8-bit data 
signal line. Communication from the host to the printer is called Forward mode, while communication from the 
printer to the host is called Reverse mode.