Справочник Пользователя для Citizen Systems BD2-2220

Скачать
Страница из 312
 
- 126 - 
GS g 0 m nL nH 
CT-S280 CT-S300 CT-S2000
CT-S4000
BD2-2220 CT-S310 
support model 
PMU2XXX 
     
 
 
[Function] 
Initializing maintenance counter 
 
[Code] 
<
1D>H<67>H<30>H<m><nL><nH> 
 
[Range] m=0 
20≦(nL+nH×256)≦70(nL=20、21、50、70、nH=0) 
 
[Outline] 
[The specification which is common to the model]
 
Set the value of resettable maintenance counter specified to 0. 
nL, nH are used to set the maintenance counter number to (nL+nH×256).
   
 
Counter Number 
Counter  Unit] 
Hex. Decimal 
14 20 
Paper-feed line[line] 
15 21 
Head powering count  [times] 
32 50 
Auto-cutter drive count  [times] 
46 70 
Product operation time[hours] 
 
[Caution]
 
• This command, if used frequently, may destroy NV memory, thus write command to NV memory 
shall be used less than  [10 times/day] as a guideline. 
• Along with processing this command, during data-writing to NV memory, printer BUSY may occur.   
During the printer BUSY, to stop receive processing, this printer prohibits the data sending 
(including real-time command) from host.