Справочник Пользователя для Citizen Systems BD2-2220

Скачать
Страница из 312
 
- 152 - 
2.2.16 Printer Function Setting Commands 
GS ( D pL pH m [a1 b1]...[ak bk] 
CT-S280 
CT-S300 
CT-S2000
CT-S4000
BD2-2220 
CT-S310 
support model 
PMU2XXX 
     
 
 
[Function]  
Enabling or disabling real-time command 
 
[Code] 
<
1D>H<28>H<44>H<pL>< pH>< m> [<a1>< b1>]…[<ak>< bk>] 
 
[Range] 
3≦(pL+pH×256)≦65535 
m=20 
a=1 
b=0、1、48、49 
 
[Outline] 
[The specification which is common to the model]
 
Enables/disables the following real-time command processing. 
 
Function 
a b 
0、48  Does not process DLE DC4 fn m t (fn = 1).    (Invalid) 
1、49  Processes DLE DC4 fn m t (fn = 1).    (Valid) 
 
• pL and pH sets the number of bytes on and after m in (pL + pH x256). 
• “a” sets the kind of real-time command. 
• “b” sets Valid or Invalid. 
• When data raw that meets the code configuring real-time command in the image data, it is 
recommended that the real-time command be set to invalid by this command. 
 
[Default] 
 
Type of Real-time Command 
Initial Value 
DLE DC4 fn m t (fn=1): Real-time output of pulse specified 
Valid