Persona C16 Card Printer Service Manual (Rev. 5.0) 
178
Replacing the Upper Ribbon Sensor Assembly (83015111)  
Refer to Drawing 830119-XX 
Estimated Repair Time:  20 minutes. 
Steps Procedure 
1
Caution:  Turn off the Printer and unplug the power cord from the 
Printer. 
2
Open the Upper Imaging Assembly. 
3
Loosen the top two corner screws (130987) found just behind the top edge of the 
Rear Cover. 
4
Close the Upper Imaging Assembly.  
5
Remove the screw (130987) by the Card Exit Ramp.  
6
Remove the Rear Cover. 
7
Open the Upper Imaging Assembly. 
8
Remove the screws (130948) from the four corners of the top cover. 
9
Close the Upper Imaging Assembly.  
10 
Lift the top cover from the Printer 
11 
Take the two screws (130990) from the Fan Guard (150312); lift the fan out of 
the Printer. 
12 
Remove the two screws (130971) that secure the Shield Sensor (810303) to the 
Sensor Mount Bracket (810221). 
13 
Take the Ribbon Sensor Assembly from the Printer. 
Continued on the next page