Справочник Пользователя для Ricoh AP505

Скачать
Страница из 80
Troubleshooting
50
4
Note
❒ Do not close the front cover re-
moving the photoconductor
unit. Otherwise, you cannot re-
place the photoconductor unit
because the photoconductor
unit holder will be closed. If you
do this by mistake, return the
photoconductor unit holder to
its original position before re-
placing the photoconductor
unit.
H
Hold the inset grips (green part)
of the new photoconductor unit,
and insert the photoconductor
unit into the photoconductor unit
holder.
When inserting the photoconduc-
tor unit, be careful not to damage
the surface of it.
Note
❒ The white powder on the photo-
conductor unit is to protect it af-
ter installation into the printer.
This white powder doesn't have
any adverse effect on the interi-
or of the printer.
I
Hold the inset grips (green part)
of the new photoconductor unit,
and push the photoconductor
unit to its original position.
J
Fix the photoconductor unit with
fastening the screws using the
screw driver.
K
Close the front cover.
Make sure that the front cover
close properly.
L
Turn on the printer’s power
switch.
Replacing the Fuser Oil Bottle 
and Ozone Filter
Replace the oil bottle and ozone filter
whenever the message shown below
appears on the panel display.
  FUSER OIL LOW
  
  ADD FUSER OIL
    
There is the fuser oil bottle and the
ozone filter in the Fuser Oil Type305.
R
 
WARNING:
TFWX300E
TFWX305E
Do not incinerate the oil bottle. 
This action could cause a fire 
or getting burned.
Spilt oil is very slippery. If oil 
is spilt, wipe it with alkaline 
cleaner. Otherwise, the oily 
surfaces can create the dan-
ger of slipping and personal 
injury.