Справочник Пользователя для Mitsubishi Electronics QD75MH2

Скачать
Страница из 838
 
 
 
5 - 14 
MELSEC-Q
 
5   DATA USED FOR POSITIONING CONTROL 
 
5.1.6 Setting items for block start data 
The "block start data" must be set when carrying out "high-level positioning control". 
The setting items for the " block start data" are shown below. 
Up to 50 points of " block start data" can be set for each axis. 
Refer to Chapter 10 "High-level Positioning Control" for details on the "high-level 
positioning control", and to Section 5.4 "List of block start data" for details on each 
setting item. 
 
High-level positioning 
control 
 
Block start data 
Block start 
(Normal start) 
Condition 
start 
Wait start 
Simultaneous 
start 
Repeated 
start 
(FOR loop) 
Repeated 
start 
(FOR 
condition) 
Da.11
 
Shape (end/continue) 
 
 
 
 
 
 
Da.12
 
Start data No. 
 
 
 
 
 
 
Da.13
 
Special start instruction 
– 
 
 
 
 
 
Da.14
 
Parameter – 
 
 
 
 
 
 
 
 :  Set as required ("–" when not set) 
 
–  :  Setting not required (This is an irrelevant item, so the setting value will be ignored. If the value is the default value or within the 
setting range, there is no problem.) 
 
 
 Checking the block start data 
Da.11
to
Da.14
are checked with the following timing. 
 
(1)  When the "Block start data" starts 
(2)  When an error check is carried out with GX Configurator-QP