Справочник Пользователя для Mitsubishi Electronics QD75MH2

Скачать
Страница из 838
 
 
 
5 - 20 
MELSEC-Q
 
5   DATA USED FOR POSITIONING CONTROL 
 
5.1.9 Types and roles of control data 
Operation of the positioning system is achieved through the execution of necessary 
controls.  (Data required for controls are given through the default values when the 
power is switched ON, which can be modified as required by the PLC program.) 
Controls are performed over system data or machine operation. 
 
 Controlling the system data : 
 
Setting and resetting QD75MH setting data (through the system control data
Cd.1
 , 
Cd.2
 
 Controlling the operation : 
 
Setting operation parameters, changing speed during operation, interrupting or 
restarting operation (through the axis control data
Cd.3
to
Cd.42
Cd.100
 to 
Cd.108
 
 
[1]   Controlling the system data 
 
 Setting and resetting the setting data 
 
Control details 
Controlled data item 
  Write setting data from buffer memory to flash ROM. 
Cd.1
  Flash ROM write request 
  Reset (initialize) parameters. 
Cd.2
  Parameter initialization request