Справочник Пользователя для Mitsubishi Electronics QD75MH2

Скачать
Страница из 838
 
 
 
5 - 117 
MELSEC-Q
 
5   DATA USED FOR POSITIONING CONTROL 
 
Da.18 Parameter 1 
 
Set the parameters as required for the "
Da.16
Condition operator". 
 
Da.16
Condition operator 
Setting value 
Setting details 
01
H
 : 
∗∗=P1 
02
H
 : 
∗∗≠P1 
03
H
 : 
∗∗≤P1 
04
H
 : 
∗∗≥P1 
05
H
 : P1
≤∗∗≤P2 
06
H
 :  
∗∗≤P1, P2≤∗∗ 
Value 
The value of P1 should be equal to or smaller than the value of 
P2. (P1
≤P2) 
If P1 is greater than P2 (P1>P2), the "condition data error" (error 
code 533) will occur. 
07
H
 : DEV=ON 
08
H
 : DEV=OFF 
Value 
(bit No.) 
Set the device bit No. 
X:  0
H
 to 1
H
, 4
H
 to 17
H
 Y:  0, 4
H
 to 17
H
 
10
H
 : Axis 1 selected 
   
E0
H
 : Axes 2, 3, and 4 selected 
Value 
(positioning data No.) 
Set the positioning data No. for starting axis 1 and/or axis 2. 
Low-order 16-bit 
:  Axis 1 positioning data No. 1 to 600 (01
H
 to 258
H
High-order 16-bit 
:  Axis 2 positioning data No. 1 to 600 (01
H
 to 258
H
 
 
Da.19 Parameter 2 
 
Set the parameters as required for the "
Da.16
Condition operator". 
 
Da.16
Condition operator 
Setting value 
Setting details 
01
H
 :  
∗∗=P1 
02
H
 : 
∗∗≠P1 
03
H
 : 
∗∗≤P1 
04
H
 : 
∗∗≥P1 
— 
Not used.  (No need to be set.) 
05
H
 :  P1
≤∗∗≤P2 
06
H
 : 
∗∗≤P1, P2≤∗∗ 
Value 
The value of P2 should be equal to or greater than the value of 
P1. (P1
≤P2) 
If P1 is greater than P2 (P1>P2), the "condition data error" (error 
code 533) will occur. 
07
H
 :  DEV=ON 
08
H
 :  DEV=OFF 
10
H
 :  Axis 1 selected 
20
H
 :  Axis 2 selected 
30
H
 :  Axes 1 and 2 selected 
— 
Not used.  (No need to be set.) 
40
H
 :  Axis 3 selected 
50
H
 :  Axes 1 and 3 selected 
60
H
 :  Axes 2 and 3 selected 
70
H
 :  Axes 1, 2, and 3 selected 
80
H
 :  Axis 4 selected 
90
H
 :  Axes 1 and 4 selected 
A0
H
 : Axes 2 and 4 selected 
B0
H
 : Axes 1, 2, and 4 selected 
C0
H
 : Axes 3 and 4 selected 
D0
H
 : Axes 1, 3, and 4 selected 
E0
H
 : Axes 2, 3, and 4 selected 
Value 
(positioning data No.) 
Set the positioning data No. for starting axis 3 and/or axis 4. 
Low-order 16-bit 
:  Axis 3 positioning data No. 1 to 600 (01
H
 to 258
H
High-order 16-bit 
:  Axis 4 positioning data No. 1 to 600 (01
H
 to 258
H