8   OPR CONTROL 
 
8.3 Fast OPR 
8.3.1 Outline of the fast OPR operation 
 Fast OPR operation 
 
In a fast OPR, positioning is carried out by a machine OPR to the "
Md.21
 
Machine feed value" stored in the QD75MH. 
The following shows the operation during a basic fast OPR start.  
 
1)  The fast OPR is started.  
2)  Positioning control begins to the "
Md.21
 Machine feed value", begins at 
speed set in the OPR parameters (
Pr.43
to
Pr.57
).  
3)  The fast OPR is completed.  
 
Machine OP
(OP position)
Pr. 46 OPR speed 
Fast OPR start
(Positioning start signal)
Md.26 Axis operation status
In OPR
Standing by
Standing by
OP
Positioning to the OP
M
 
Fig. 8.10 Fast OPR