1   PRODUCT OUTLINE 
 
 
Overview of acceleration/deceleration processing control
 
Acceleration/deceleration processing for the positioning processing, manual pulse-
generator processing, OPR processing and JOG processing is performed using the 
user-specified method, acceleration time and deceleration time. 
 
(1)   Acceleration/deceleration method 
There are two types of acceleration and deceleration processing: the automatic 
trapezoidal acceleration/deceleration processing method and S-pattern 
acceleration/deceleration processing method. A detailed parameter is used to set 
which method is used. The specified acceleration/deceleration method is applied 
to all accelerations and decelerations when starting and completing positioning 
processing, OPR processing and JOG processing, as well as when changing the 
speed. 
(a)   Automatic trapezoidal acceleration/deceleration processing method 
This is a method in which linear acceleration/deceleration is carried out 
based on the acceleration time, deceleration time, and speed limit value set 
by the user. 
 
Velocity
Time
 
 
(b)   S-pattern acceleration/deceleration processing method 
This method reduces the load on the motor when starting and stopping. 
This is a method in which acceleration/deceleration is carried out gradually, 
based on the acceleration time, deceleration time, speed limit value, and 
"
Pr.35
 S-pattern proportion" (1 to 100%) set by the user. 
 
Velocity
Time
 
 
(2)   Acceleration time, deceleration time, sudden-stop deceleration time 
(a)   For types each of the acceleration time and deceleration time for positioning 
control can be set using basic parameters 2 and detailed parameters 2. 
  • Acceleration time…….The time elapses before the speed of 0 reaches  
                                         the limit value. 
  • Deceleration time…….The time elapses before the speed at the limit  
                                         value reaches 0. 
 
(b)   The sudden-stop deceleration time (1 to 8388608 ms) is set using the 
acceleration time/deceleration time setting size selection of detailed 
parameters 2.