9.2 Setting the positioning data  
9.2.1 Relation between each control and positioning data 
The setting requirements and details for the setting items of the positioning data to be 
set differ according to the "
Da.2
 Control system".  
The following table shows the positioning data setting items corresponding to the 
different types of control. Details and settings for the operation of each control are 
shown in Section 9.2.2 and subsequent sections.  
(In this section, it is assumed that the positioning data setting is carried out using GX 
Configurator-QP.) 
 
Position control 
Speed control 
Major positioning control 
 
 
 
 
 
 
Positioning data setting items 
1-axis linear 
control 
2-axis linear 
interpolation 
control 
3-axis linear 
interpolation 
control 
4-axis linear 
interpolation 
control
 
1-axis fixed-feed 
control 
2-axis fixed-feed 
control 
3-axis fixed-feed 
control 
4-axis fixed-feed 
control
 
2-axis circular 
interpolation 
control 
1-axis, 2-axis, 
3-axis, 4-axis 
Speed control 
Speed- 
position 
switching 
control 
Position- 
speed 
switching 
control 
Independent 
positioning control 
(Positioning complete) 
 
 
 
 
 
 
Continuous positioning 
control 
 
 
 
 
 
 
 Da.1  
Operation 
pattern 
Continuous path 
control 
 
 
 
 
 
 
 Da.2 
 
Control system 
Linear 1 
Linear 2 
Linear 3 
Linear 4 
 
Fixed-feed 1 
Fixed-feed 2 
Fixed-feed 3 
Fixed-feed 4 
 
Circular sub 
Circular right 
Circular left 
 
Forward run 
speed 1 
Reverse run 
speed 1 
Forward run 
speed 2 
Reverse run 
speed 2 
Forward run 
speed 3 
Reverse run 
speed 3 
Forward run 
speed 4 
Reverse run 
speed 4 
Forward run 
speed/posi-
tion 
Reverse run 
speed/posi-
tion 
 
Forward run 
position/speed 
 
Reverse run 
position/speed 
 Da.3 
 
Acceleration time No. 
 
 
 
 
 
 
 Da.4 
 
Deceleration time No. 
 
 
 
 
 
 
 Da.5 
 
Axis to be interpolated 
:   2 - a xi s   –: 1, 3, 4-axis 
– – 
 Da.6 
 
Positioning address/movement 
amount 
 
 
 
– 
 
 
 Da.7 
 
Arc address 
– 
– 
 
– – – 
 Da.8 
 
Command speed 
 
 
 
 
 
 
 Da.9 
 
Dwell time 
 
 
 
 
 
 
 Da.10  M code 
 
 
 
 
 
 
 
 
 :  Always set            : Set as required ("–" when not set) 
 
 :  Setting not possible (If setting is made, an error (error code: 516) will occur at a start.) 
 
–  :  Setting not required (Setting value is invalid. Use the initial values or setting values within a range where no error occurs.) 
 
 :  The "ABS (absolute) system" or "INC (incremental) system" can be used for the control system.