9   MAJOR POSITIONING CONTROL 
 
 Positioning data setting example 
 
The following table shows setting examples when "1-axis fixed-feed control (fixed-
feed 1)" is set in positioning data No. 1 of axis 1.  
 
Setting item 
Setting 
example 
Setting details 
 Da.1  Operation pattern 
Positioning 
complete 
Set "Positioning complete" assuming the next positioning data will not 
be executed. 
 Da.2  Control system 
Fixed-feed 1  Set 1-axis fixed-feed control. 
 Da.3  Acceleration time No. 
Designate the value set in "
Pr.25
 Acceleration time 1" as the 
acceleration time at start. 
 Da.4  
Deceleration time 
No. 
Designate the value set in "
Pr.10
 Deceleration time 0" as the 
deceleration time at deceleration. 
 Da.5  
Axis to be 
interpolated 
– 
Setting not required (setting value will be ignored). 
 Da.6  
Positioning address/ 
movement amount 
8000.0µm  
Set the positioning address. (Assuming "mm" is set in "
Pr.1
 Unit 
setting".) 
 Da.7  Arc address 
– 
Setting not required (setting value will be ignored). 
 Da.8  Command speed 
6000.00mm/
min 
Set the speed during movement to the positioning address. 
 Da.9  Dwell time 
500ms 
Set the time the machine dwells after the positioning stop (pulse output 
stop) to the output of the positioning complete signal. 
Ax
is 1   Positioning data N
o. 1 
 Da.10 
M code 
10 
Set this when other sub operation commands are issued in combination 
with the No. 1 positioning data. 
 
   * Refer to Section 5.3 "List of positioning data" for information on the setting details.