Справочник Пользователя для Mitsubishi Electronics QD75MH2

Скачать
Страница из 838
 
 
 
9 - 50 
MELSEC-Q
 
9   MAJOR POSITIONING CONTROL 
 
 Restrictions 
 
(1)  An axis error "Continuous path control not possible (error code: 516)" will 
occur and the operation cannot start if "continuous path control" is set in 
"
Da.1
 Operation pattern". ("Continuous path control" cannot be set in fixed-
feed control.) 
(2)  "Fixed-feed" cannot be set in "
Da.2
 Control system" in the positioning data 
when "continuous path control" has been set in "
Da.1
 Operation pattern" of 
the immediately prior positioning data. (For example, if the operation pattern of 
positioning data No. 1 is "continuous path control", fixed-feed control cannot 
be set in positioning data No. 2.) An axis error "Continuous path control not 
possible (error code: 516)" will occur and the machine will carry out a 
deceleration stop if this type of setting is carried out.  
 
 Positioning data setting example 
 
[Reference axis is designated as axis 1.] 
The following table shows setting examples when "3-axis fixed-feed control (fixed-
feed 3)" is set in positioning data No. 1 of axis 1. (The required values are also set 
in positioning data No. 1 of axis 2 and axis 3.)