Справочник Пользователя для Mitsubishi Electronics QD75MH2

Скачать
Страница из 838
 
 
 
1 - 21 
MELSEC-Q
 
1   PRODUCT OUTLINE 
 
 QD75MH   Manual pulse generator 
The QD75MH and manual pulse generator communicate the following data via the 
external device connection connector. 
(The manual pulse generator should be connected to an external device connection 
connector for axis 1 or for axes 1 and 2.) 
 
Direction 
Communication 
QD75MH   Manual pulse generator 
Manual pulse generator   QD75MH 
Pulse signal 
– 
• Manual pulse generator A-phase 
• Manual pulse generator B-phase 
 
 QD75MH   External signal 
The QD75MH and external signal communicate the following data via the external 
device connection connector. 
 
Direction 
Communication 
QD75MH   External signal 
External signal   QD75MH 
Control signal 
– 
 Forced stop input signal 
 Upper/lower limit signal 
 External command signal/switching 
signal 
 Stop signal 
 Near-point dog signal