9   MAJOR POSITIONING CONTROL 
 
 Current feed value during 3-axis speed control 
The following table shows the "
Md.20
Current feed value" during 3-axis speed 
control corresponding to the "
Pr.21
Current feed value during speed control" 
settings.  (Note that the reference axis setting values are used for parameters.) 
 
Pr.21
Current feed value during speed 
control" setting 
Md.20
Current feed value 
0: Do not update current feed value 
The current feed value at speed control start 
is maintained. 
1: Update current feed value 
The current feed value is updated. 
2: Zero clear current feed value 
The current feed value is fixed at 0. 
 
V
t
In speed control
Current feed value during speed control start is maintained
(a) Current feed value not updated
t
Current feed value is updated
(b) Current feed value updated
(c) Current feed value zero cleared
t
0
In speed control
In speed control
V
V
 
 
 Restrictions 
(1)  Set "Positioning complete" in "
Da.1
Operation pattern". An axis error 
"Continuous path control not possible (error code: 516)" will occur and the 
operation cannot start if "continuous positioning control" or "continuous path 
control" is set. ("Continuous positioning control" and "continuous path control" 
cannot be set in speed control.) 
(2)  Set the WITH mode in "
Pr.18
M code ON signal output timing" when using 
an M code. The M code will not be output, and the M code ON signal will not 
turn ON if the AFTER mode is set. 
(3)  Set the "reference axis speed" in "
Pr.20
Interpolation speed designation 
method". An "Interpolation mode error (error code: 523)" will occur and the 
operation cannot start if a composite speed is set.