10   HIGH-LEVEL POSITIONING CONTROL 
 
10.3.3 Condition start 
In a "condition start", the "condition data" conditional judgment designated in "
 Da.14 
 
Parameter" is carried out for the positioning data set in "
 Da.12 
 Start data No.". If the 
conditions have been established, the " block start data" set in "1: condition start" is 
executed. If the conditions have not been established, that " block start data" will be 
ignored, and the "block start data" of the next point will be executed.  
 
Section [2] shows a control example where the " block start data" and "positioning 
data" are set as shown in section [1].  
 
[1]   Setting examples 
 
(1)   Block start data setting example 
 
Axis 1 block 
start data 
 Da.11   
Shape 
 Da.12   
Start data No. 
 Da.13   
Special start 
instruction 
 Da.14   
Parameter 
1st point 
1: Continue 
1: Condition start 
2nd point 
1: Continue 
10 
1: Condition start 
3rd point 
0: End 
50 
0: Block start 
– 
 
 
 
 
 
 
 
 
 
 
 
 The "condition data Nos." have been set in "  Da.14   Parameter". 
 
(2)   Positioning data setting example 
 
Axis 1 position-
ing data No. 
 Da.1  
Operation pattern 
01: Continuous positioning control 
01: Continuous positioning control 
00: Positioning complete 
 
 
10 
11: Continuous path control 
11 
11: Continuous path control 
12 
00: Positioning complete 
 
 
50 
00: Positioning complete 
 
 
 
[2]   Control examples 
The following shows the control executed when the " block start data" of the 1st 
point of axis 1 is set as shown in section [1] and started.  
 
<1>  The conditional judgment set in "condition data No. 1" is carried out before 
execution of the axis 1 "positioning data No. 1". 
  Conditions established   Execute positioning data No. 1, 2, and 3   
Go to <2>. 
  Conditions not established   Go to <2>. 
 
<2>  The conditional judgment set in "condition data No. 2" is carried out before 
execution of the axis 1 "positioning data No. 10". 
  Conditions established   Execute positioning data No. 10, 11, and 12 
 Go to <3>. 
  Conditions not established   Go to <3>. 
 
<3>  Execute axis 1 "positioning data No. 50" and stop the control.