Справочник Пользователя для Mitsubishi Electronics QD75MH2

Скачать
Страница из 838
 
 
 
10 - 19 
MELSEC-Q
 
10   HIGH-LEVEL POSITIONING CONTROL 
 
10.4.2 Condition data setting examples 
The following shows setting examples for "condition data".  
 
(1)   Setting the device ON/OFF as a condition 
 
[Condition] Device "X0" (=QD75 READY) is OFF 
 
 Da.15   
Condition target 
 Da.16   
Condition 
operator 
 Da.17   
Address 
 Da.18   
Parameter 1 
 Da.19   
Parameter 2 
01
H
: Device X 
08
H
DEV=OFF 
– 0 – 
 
(2)   Setting the numeric value stored in the "buffer memory" as a 
condition 
 
[Condition] 
The value stored in buffer memory addresses "800, 801" (= "
Md.20
Current 
feed value") is "1000" or larger. 
 
 Da.15   
Condition target 
 Da.16   
Condition 
operator 
 Da.17   
Address 
 Da.18   
Parameter 1 
 Da.19   
Parameter 2 
04
H
: Buffer memory 
(2 words) 
04
H
 
≥ P1 
800 1000  – 
 
(3)   Designating the axis and positioning data No. to be simultaneously 
started in "simultaneous start" 
 
[Condition] 
Simultaneously starting "axis 2 positioning data No.3". 
 
 Da.15   
Condition target 
 Da.16   
Condition 
operator 
 Da.17   
Address 
 Da.18   
Parameter 1 
 Da.19   
Parameter 2 
05
H
: Positioning 
data No. 
20
H
: Axis 2 
designation 
– 
High-order 16 
bits "0003
H
–