12 - 25 
MELSEC-Q
 
12   CONTROL SUB FUNCTIONS 
 
12.4.2 Torque limit function 
The "torque limit function" limits the generated torque to a value within the "torque limit 
value" setting range when the torque generated in the servomotor exceeds the "torque 
limit value".  
The "torque limit function" protects the deceleration function, limits the power of the 
operation pressing against the stopper, etc. It controls the operation so that 
unnecessary force is not applied to the load and machine.  
 
The details shown below explain about the "torque limit function".  
  [1] Relation between the torque limit function and various controls 
  [2] Control details 
  [3] Precautions during control 
  [4] Setting the torque limit function 
 
[1]   Relation between the torque limit function and various controls 
The following table shows the relation of the "torque limit function" and various 
controls.  
 
Control type 
Torque limit 
function 
Torque limit value   
Machine OPR control 
 
 "
Pr.17
Torque limit setting 
value" or "  Cd.101  Torque 
output setting value". 
 After the "
Pr.47
 Creep 
speed" is reached, this value 
becomes the "
Pr.54
 OPR 
torque limit value". 
OPR 
control 
Fast OPR control 
 
1-axis linear control 
 
2 to 4-axes linear 
interpolation control 
 
1-axis fixed-feed control 
 
2 to 4-axes fixed-feed 
control (interpolation) 
 
Position 
control 
2-axis circular interpolation 
control 
 
1 to 4-axes Speed control 
 
Speed-position switching control 
Position-speed switching control 
 
 "
Pr.17
Torque limit setting 
value" or "  Cd.101  Torque 
output setting value". 
Current value changing 
– 
Major 
positioning 
control 
Other 
control 
JUMP instruction, NOP 
instruction, LOOP to 
LEND 
– 
 Setting value is invalid. 
JOG operation, Inching operation 
 
Manual 
control 
Manual pulse generator operation 
 
 "
Pr.17
Torque limit setting 
value" or "  Cd.101  Torque 
output setting value". 
 
  :  Set when required (Set to " – " when not used.) 
–  :  Setting not required (Setting value is invalid. Use the initial values or setting values 
within a range where no error occurs.) 
  :  Shows the torque limit value when "
Cd.22
 New torque value" is set to "0".