15   TROUBLESHOOTING 
 
 
 
 
Related buffer memory 
address 
 
 
 
Axis 1  Axis 2  Axis 3  Axis 4 
Servo 
amplifier 
status of 
the warning 
occurrence. 
Check point 
Corrective action 
Repair cable or battery changed. 
 
 
 
— — — — 
 
Change battery. 
In-position range 
 
 
30110 30310 30510 30710 
Remove the cause of droop pulse occurrence. 
Creep speed 
 
 
 
76, 77 
226, 
227 
376, 
377 
526, 
527 
 
Reduce creep speed. 
 
 
 
— — — — 
 Change 
battery. 
 
 
 
 
 
 
— — — — 
Call the status display 
and check regenerative 
load ratio. 
• Reduce frequency of positioning. 
• Change regenerative brake option for the one with 
larger capacity. 
• Reduce load. 
 
 
 
 
— — — — 
Servo ON 
continued 
Refer to error code 
(2050, 2051) (Refer to 
Section 15.2.3) 
Refer to error code (2050, 2051) (Refer to Section 
15.2.3) 
 
 
— — — — 
Take noise suppression measures. 
 
 
— — — — 
• Servo ON 
continued 
• Home 
position 
request On 
 
Change servomotor. 
 
 
 
Refer to Section  
5.2.7 to 5.2.10 
Servo ON 
continued 
 
Set the parameter properly. 
 
 
Forced stop input selection 
 
30104 30304 30504 30704 
 
Check for safety and release the forced stop. 
 
 
 
 
Forced stop valid/invalid 
selection 
Check continuity status 
of the external device 
connection cable. 
• Check for safety and release the forced stop. 
• Repair cable or battery changed. 
 
 
 
35 — — — 
Servo OFF 
 Change 
QD75MH. 
 
 
 
Change the cooling fan of the servo amplifier. 
 
 
 
— — — — 
Servo ON 
continued 
 
Change servo amplifier.