Справочник Пользователя для IBM RS/6000 44P

Скачать
Страница из 216
OS Surveillance Setup Menu
1. Surveillance:
Currently Enabled
2. Surveillance Time Interval:
Currently 5 or Not Applicable
3. Surveillance Delay:
Currently 10 or Not Applicable
98. Return to Previous Menu
v
Surveillance
Can be set to Enabled or Disabled.
v
Surveillance Time Interval
Can be set to any number from 1 to 255 minutes.
v
Surveillance Delay
Can be set to any number from 0 to 255 minutes.
Surveillance time interval and surveillance delay can only be changed after surveillance
is enabled.
Refer to “Service Processor System Monitoring - Surveillance” on page 65 for more
information about surveillance.
v
Reset Service Processor
Allows the user to reinitialize the service processor.
v
Reprogram Service Processor Flash EPROM
This is an automatic process.
Serial Port Snoop Setup Menu
This menu can be used to setup Serial Port Snooping, in which the user can configure
serial port 1 as a
catch-all
reset device.:
From the main Service Processor menu, select option 1, Service Processor setup, then
select option 8 (Serial Port Snoop Setup Menu).
SERIAL PORT SNOOP SETUP MENU
1. System reset string:
Currently Unassigned
2. Snoop Serial Port:
Currently Unassigned
98. Return to Previous Menu
1>
Use the system reset string option to enter the system reset string, which resets the
machine when it is detected on the main console on Serial Port 1.
Chapter 3. Using the Service Processor
47