Справочник Пользователя для HP (Hewlett-Packard) 076064 REV C
4-6
Media Feed Calibration
Media Feed
Calibration
Calibration
This calibration allows you to calibrate the accuracy of the
Media Feed process. You may want to do this when printed out-
put must be precise, as when tiling output. This calibration is
not included in the AutoSet process.
Media Feed process. You may want to do this when printed out-
put must be precise, as when tiling output. This calibration is
not included in the AutoSet process.
To perform this procedure you need a one-meter metric ruler.
1.
Press the
a (Options) key on the control panel to display the
menus.
2.
Press the
c key repeatedly to highlight the Calibrate Printer
option.
3.
Press the
e (Menu Select) key to display the Calibrate Printer
menu.
4.
Press the
c key repeatedly to highlight the Media Feed
Calibration option.
5.
Press
e (Menu Select).
The control panel displays this prompt:
Print media feed
calibration marks?
6.
Press
f (Proceed).
The printer prints a calibration page.
7.
When the calibration page has printed, cut it from the printer
and lay it on a flat surface.
and lay it on a flat surface.
8.
Measure the distance between the cross-shaped targets
marked “MEDIA FEED CALIBRATION MARK.”
marked “MEDIA FEED CALIBRATION MARK.”
The distance should be exactly 900 mm.
9.
Using the control panel, enter the measured distance.
You can enter the distance to a precision of 0.5 mm.
10. Press
f (Proceed).
Media feed calibration is complete.