Справочник Пользователя для IBM Type 7977

Скачать
Страница из 124
v
   
The
 
hot-swap
 
bays
 
are
 
arranged
 
vertically
 
in
 
the
 
standard
 
hard
 
disk
 
drive
 
cage;
 
the
 
bay
 
numbers
 
are
 
0
 
through
 
7
 
(from
 
top
 
to
 
bottom)
 
on
 
models
 
with
 
eight
 
hard
 
disk
 
drives
 
and
 
0
 
through
 
11
 
(from
 
top
 
to
 
bottom)
 
on
 
models
 
with
 
twelve
 
hard
 
disk
 
drives.
 
v
   
For
 
a
 
list
 
of
 
supported
 
optional
 
devices
 
for
 
the
 
server,
 
see
 
 
v
   
Inspect
 
the
 
drive
 
tray
 
for
 
signs
 
of
 
damage.
 
v
   
Make
 
sure
 
that
 
the
 
drive
 
is
 
correctly
 
installed
 
in
 
the
 
tray.
 
v
   
See
 
the
 
documentation
 
for
 
the
 
ServeRAID-8k,
 
ServeRAID-8s,
 
and
 
the
 
optional
 
ServeRAID-10is
 
SAS
 
controllers
 
for
 
instructions
 
for
 
installing
 
a
 
hard
 
disk
 
drive.
 
v
   
All
 
hot-swap
 
drives
 
in
 
the
 
server
 
must
 
have
 
the
 
same
 
throughput
 
speed
 
rating;
 
using
 
drives
 
with
 
different
 
speed
 
ratings
 
might
 
cause
 
all
 
drives
 
to
 
operate
 
at
 
the
 
throughput
 
speed
 
of
 
the
 
slowest
 
drive.
 
v
   
To
 
minimize
 
the
 
possibility
 
of
 
damage
 
to
 
the
 
hard
 
disk
 
drives
 
when
 
you
 
are
 
installing
 
them
 
in
 
a
 
rack
 
configuration,
 
install
 
the
 
server
 
in
 
the
 
rack
 
before
 
you
 
install
 
the
 
hard
 
disk
 
drives.
 
v
   
You
 
do
 
not
 
have
 
to
 
turn
 
off
 
the
 
server
 
to
 
install
 
hot-swap
 
drives
 
in
 
the
 
hot-swap
 
drive
 
bays.
 
However,
 
you
 
must
 
turn
 
off
 
the
 
server
 
when
 
you
 
perform
 
any
 
steps
 
that
 
involve
 
installing
 
or
 
removing
 
cables.
 
v
   
Do
 
not
 
mix
 
SAS
 
and
 
SATA
 
drives
 
in
 
the
 
same
 
array.
 
v
   
The
 
drive
 
ID
 
of
 
each
 
hot-swap
 
hard
 
disk
 
drive
 
is
 
printed
 
on
 
the
 
label
 
on
 
the
 
side
 
of
 
the
 
drive
 
cage.
The
 
following
 
illustration
 
shows
 
how
 
to
 
install
 
a
 
hot-swap
 
hard
 
disk
 
drive.
 
EMC shield
Hard disk drive
Drive tray
Drive tray handle
(in open position)
  
 
To
 
install
 
a
 
hot-swap
 
hard
 
disk
 
drive,
 
complete
 
the
 
following
 
steps:
 
1.
   
Read
 
the
 
safety
 
information
 
that
 
begins
 
on
 
page
 
vii
 
and
 
2.
   
Remove
 
the
 
bezel
 
from
 
the
 
server.
 
3.
   
Remove
 
the
 
EMC
 
shield
 
from
 
one
 
of
 
the
 
empty
 
hot-swap
 
bays.
 
4.
   
Make
 
sure
 
that
 
the
 
tray
 
handle
 
is
 
open;
 
then,
 
install
 
the
 
hard
 
disk
 
drive
 
into
 
the
 
hot-swap
 
bay.
Notes:
  
1.
   
When
 
you
 
turn
 
on
 
the
 
server,
 
check
 
the
 
hard
 
disk
 
drive
 
status
 
LEDs
 
to
 
verify
 
that
 
the
 
hard
 
disk
 
drive
 
is
 
operating
 
correctly.
 
If
 
the
 
amber
 
hard
 
disk
 
drive
 
status
 
LED
 
for
 
a
 
drive
 
is
 
lit
 
continuously,
 
that
 
drive
 
is
 
faulty
 
and
 
must
 
be
 
replaced.
 
If
 
the
 
green
 
hard
 
disk
 
drive
 
activity
 
LED
 
is
 
flashing,
 
the
 
drive
 
is
 
being
 
accessed.
 
 
24
 
IBM
 
System
 
x3500
 
Type
 
7977:
 
Installation
 
Guide