Справочник Пользователя для IBM Type 7977

Скачать
Страница из 124
grouping
 
the
 
first
 
two
 
physical
 
drives
 
in
 
the
 
ServeRAID
 
Manager
 
tree
 
into
 
an
 
array
 
and
 
creating
 
a
 
RAID
 
level-1
 
logical
 
drive.
 
If
 
you
 
select
 
custom
 
configuration,
 
you
 
can
 
select
 
the
 
two
 
physical
 
drives
 
that
 
you
 
want
 
to
 
group
 
into
 
an
 
array
 
and
 
create
 
a
 
hot-spare
 
drive.
 
Using
 
express
 
configuration:
   
To
 
use
 
express
 
configuration,
 
complete
 
the
 
following
 
steps:
 
1.
   
In
 
the
 
ServeRAID
 
Manager
 
tree,
 
click
 
the
 
controller.
 
2.
   
Click
 
Express
 
configuration.
 
3.
   
Click
 
Next.
 
The
 
“Configuration
 
summary”
 
window
 
opens.
 
4.
   
In
 
the
 
“Configuration
 
summary”
 
window,
 
review
 
the
 
information.
 
To
 
change
 
the
 
configuration,
 
click
 
Modify
 
arrays.
 
5.
   
Click
 
Apply;
 
when
 
you
 
are
 
asked
 
whether
 
you
 
want
 
to
 
apply
 
the
 
new
 
configuration,
 
click
 
Yes.
 
The
 
configuration
 
is
 
saved
 
in
 
the
 
controller
 
and
 
in
 
the
 
physical
 
drives.
 
6.
   
Exit
 
from
 
ServeRAID
 
Manager
 
and
 
remove
 
the
 
CD
 
from
 
the
 
CD
 
drive.
 
7.
   
Restart
 
the
 
server.
Using
 
custom
 
configuration:
   
To
 
use
 
custom
 
configuration,
 
complete
 
the
 
following
 
steps:
 
 
1.
   
In
 
the
 
ServeRAID
 
Manager
 
tree,
 
click
 
the
 
controller.
 
 
2.
   
Click
 
Custom
 
configuration.
 
 
3.
   
Click
 
Next.
 
The
 
“Create
 
arrays”
 
window
 
opens.
 
 
4.
   
From
 
the
 
list
 
of
 
ready
 
drives,
 
select
 
the
 
two
 
drives
 
that
 
you
 
want
 
to
 
group
 
into
 
the
 
array.
 
 
5.
   
Click
 
the
 
(Add
 
selected
 
drives)
 
icon
 
to
 
add
 
the
 
drives
 
to
 
the
 
array.
 
 
6.
   
If
 
you
 
want
 
to
 
configure
 
a
 
hot-spare
 
drive,
 
complete
 
the
 
following
 
steps:
 
a.
   
Click
 
the
 
Spares
 
tab.
 
b.
   
Select
 
the
 
physical
 
drive
 
that
 
you
 
want
 
to
 
designate
 
as
 
the
 
hot-spare
 
drive,
 
and
 
click
 
the
 
(Add
 
selected
 
drives)
 
icon.
 
7.
   
Click
 
Next.
 
The
 
“Configuration
 
summary”
 
window
 
opens.
 
 
8.
   
Review
 
the
 
information
 
in
 
the
 
“Configuration
 
summary”
 
window.
 
To
 
change
 
the
 
configuration,
 
click
 
Back.
 
 
9.
   
Click
 
Apply;
 
then,
 
click
 
Yes
 
when
 
asked
 
if
 
you
 
want
 
to
 
apply
 
the
 
new
 
configuration.
 
The
 
configuration
 
is
 
saved
 
in
 
the
 
controller
 
and
 
in
 
the
 
physical
 
drives.
 
10.
   
Exit
 
from
 
ServeRAID
 
Manager
 
and
 
remove
 
the
 
CD
 
from
 
the
 
CD-RW/DVD
 
drive.
 
11.
   
Restart
 
the
 
server.
Viewing
 
the
 
configuration
 
You
 
can
 
use
 
ServeRAID
 
Manager
 
to
 
view
 
information
 
about
 
RAID
 
controllers
 
and
 
the
 
RAID
 
subsystem
 
(such
 
as
 
arrays,
 
logical
 
drives,
 
hot-spare
 
drives,
 
and
 
physical
 
drives).
 
When
 
you
 
click
 
an
 
object
 
in
 
the
 
ServeRAID
 
Manager
 
tree,
 
information
 
about
 
that
 
object
 
is
 
displayed
 
in
 
the
 
right
 
pane.
 
To
 
display
 
a
 
list
 
of
 
available
 
actions
 
for
 
an
 
object,
 
click
 
the
 
object
 
and
 
click
 
Actions.
 
 
60
 
IBM
 
System
 
x3500
 
Type
 
7977:
 
Installation
 
Guide