Table 17. MCT command definitions (continued)
DEC
HEX
MCT
Default
Min
Max
204
CC
Scan
1
storage template #2 predefined
location X3
205
CD
Scan
1
storage template #2 predefined
location Y3
206
CE
Scan
1
storage template #2 predefined
location DX3
207
CF
Scan
1
storage template #2 predefined
location DY3
Notes:
Setup commands
Setup commands change character font, intercharacter spacing, and the target print
station.
Set print mode
EIA-232 Syntax:
ESC ! or X'1B;21;n'
where:
n
Specifies print characteristics, such as user-defined thermal and
impact code pages.
Bit Number
Function
Bit=0
Bit=1
Thermal
Impact
(LSB) 0
Char/Page 0
See Below
See Below
yes
yes
1
Char/Page 1
See Below
See Below
yes
yes
2
Overline
Cancel
Set
yes
no
3
Emphasized
Cancel
Set
yes
yes
4
Double-high
Cancel
Set
yes
yes
5
Double-wide
Cancel
Set
yes
yes
6
Inverted Mode
Cancel
Set
yes
no
(MSB) 7
Underlined
Cancel
Set
yes
no
Table 18. Fonts for Models TI3, TI4, TG3, TG4, TG8, TG9, TI8, TI9, TF6, and TM6
Bit 0
Bit 1
User-Defined Thermal
Code Page
User-Defined Impact Code
Page @ Density
Resident
Thermal
Resident
Impact
0
0
Code Page 1
Code Page 1 @ 150 half-dots
per inch
Font A
Font A
1
0
Code Page 2
Code Page 1 @ 120 half-dots
per inch
Font B
Font B
0
1
Code Page 3
Code Page 2 @ 150 half-dots
per inch
Font C
Font A
1
1
Code Page 4
Code Page 2 @ 120 half-dots
per inch
Reserved
Font B
1.
Updated April 2, 2009
Appendix D. EIA-232 programming information