Chapter 5. Replacing Supplies   
5–39
Cleaning the Separation Corona Wire
When you replace a photoconductor drum cartridge, you should also clean 
the separation corona wire. Use the following procedure to clean the 
separation corona wire.
1. Open the top cover to see the separation corona unit and the wire 
cleaner.
 
2. Remove the wire cleaner from inside the printer.
 
The separation corona 
wire is very thin and delicate, so be careful not to break it.
3. Put the padded end of the wire cleaner on the separation corona unit.